Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Hazard Mater ; 456: 131708, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: covidwho-2328341

RESUMO

As a typical disinfectant, the use of benzyl dodecyl dimethyl ammonium bromide (BDAB) has dramatically increased since the emergence of SARS-CoV-2, posing a threat to environmental balance and human health. Screening BDAB co-metabolic degrading bacteria is required for efficient microbial degradation. Conventional methods for screening co-metabolic degrading bacteria are laborious and time-consuming, especially when the number of strains is large. This study aimed to develop a novel method for the rapid screening of BDAB co-metabolic degrading bacteria from the cultured solid medium using near-infrared hyperspectral imaging (NIR-HSI) technology. Based on NIR spectra, the concentration of BDAB in the solid medium can be well predicted by partial least squares regression (PLSR) models, non-destructively and rapidly, with Rc2 > 0.872 and Rcv2 > 0.870. The results show that the predicted BDAB concentrations decrease after degrading bacteria utilization, comparing with the regions where no degrading bacteria grew. The proposed method was applied to directly identify the BDAB co-metabolic degrading bacteria cultured on the solid medium, and two kinds of co-metabolic degrading bacteria RQR-1 and BDAB-1 were correctly identified. This method provides a high-efficiency method for screening BDAB co-metabolic degrading bacteria from a large number of bacteria.


Assuntos
Compostos de Amônio , COVID-19 , Humanos , Imageamento Hiperespectral , Espectroscopia de Luz Próxima ao Infravermelho/métodos , SARS-CoV-2 , Tecnologia , Análise dos Mínimos Quadrados , Bactérias
2.
Adv Exp Med Biol ; 1395: 205-209, 2022.
Artigo em Inglês | MEDLINE | ID: covidwho-2310010

RESUMO

The Internet of Medical Things (IoMT) system plays a role in various areas of social activity, including healthcare. Telemetry of cardiovascular function, such as blood pressure and pulse, in daily life is useful in the treatment of cardiovascular disease and stress management. However, until now, brain function monitoring technology has not been installed in the IoMT system.In this study, we used near-infrared spectroscopy (NIRS) installed in the IoMT system to evaluate whether consumers who are not medical experts can measure their own brain function correctly. In addition, the IoMT system was used to assess the long-term effects of physical exercise on physical and mental health.We studied a total of 119 healthy adults recruited from a fitness gym in Koriyama, Japan. After receiving instruction in the usage of the IoMT monitoring system including NIRS, the subjects monitored their physical and mental conditions by themselves when they visited the gym. We evaluated the relations between blood pressure (BP), pulse rate (PR), body weight (BW) and age. In addition, we evaluated the left/right asymmetry of the prefrontal cortex (PFC) at rest and BP. We calculated the laterality index at rest (LIR) for assessment of left/right asymmetry of PFC activity; a positive LIR (>0) indicates right-dominant PFC activity associated with higher stress responses, while a negative LIR (<0) indicates left-dominant PFC activity associated with lower stress responses. We studied 47 out of 119 cases who monitored their physiological conditions before and after physical exercise for 6 months for this study.The results showed that the systolic blood pressure and mean blood pressure (p < 0.05) were significantly reduced after the physical exercise for 6 months; body weight did not change significantly (p > 0.05). In addition, NIRS demonstrated that LIR changed to plus values from minus values after exercise (p < 0.01).These results show that (1) consumers who are not-medical experts can measure their own brain function correctly using NIRS; (2) after long-term physical exercise, systemic blood pressure decreased, associated with modulation of PFC activity (i.e., from right-dominant PFC activity to left-dominant activity), indicating that long-term physical exercises caused relaxation in the brain and the autonomic nervous system.


Assuntos
Córtex Pré-Frontal , Espectroscopia de Luz Próxima ao Infravermelho , Adulto , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Córtex Pré-Frontal/fisiologia , Lateralidade Funcional/fisiologia , Terapia por Exercício , Arritmias Cardíacas , Peso Corporal
3.
Sci Rep ; 12(1): 18024, 2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: covidwho-2087299

RESUMO

As the rate of vaccination against COVID-19 is increasing, demand for overseas travel is also increasing. Despite people's preference for duty-free shopping, previous studies reported that duty-free shopping increases impulse buying behavior. There are also self-reported tools to measure their impulse buying behavior, but it has the disadvantage of relying on the human memory and perception. Therefore, we propose a Brain-Computer Interface (BCI)-based brain signal processing methodology to supplement these limitations and to reduce ambiguity and conjecture of data. To achieve this goal, we focused on the brain's prefrontal cortex (PFC) activity, which supervises human decision-making and is closely related to impulse buying behavior. The PFC activation is observed by recording signals using a functional near-infrared spectroscopy (fNIRS) while inducing impulse buying behavior in virtual computing environments. We found that impulse buying behaviors were not only higher in online duty-free shops than in online regular stores, but the fNIRS signals were also different on the two sites. We also achieved an average accuracy of 93.78% in detecting impulse buying patterns using a support vector machine. These results were identical to the people's self-reported responses. This study provides evidence as a potential biomarker for detecting impulse buying behavior with fNIRS.


Assuntos
Interfaces Cérebro-Computador , COVID-19 , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Córtex Pré-Frontal/diagnóstico por imagem , Córtex Pré-Frontal/fisiologia , Biomarcadores
4.
Sensors (Basel) ; 22(19)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: covidwho-2043923

RESUMO

The worldwide outbreak of the novel Coronavirus (COVID-19) has highlighted the need for a screening and monitoring system for infectious respiratory diseases in the acute and chronic phase. The purpose of this study was to examine the feasibility of using a wearable near-infrared spectroscopy (NIRS) sensor to collect respiratory signals and distinguish between normal and simulated pathological breathing. Twenty-one healthy adults participated in an experiment that examined five separate breathing conditions. Respiratory signals were collected with a continuous-wave NIRS sensor (PortaLite, Artinis Medical Systems) affixed over the sternal manubrium. Following a three-minute baseline, participants began five minutes of imposed difficult breathing using a respiratory trainer. After a five minute recovery period, participants began five minutes of imposed rapid and shallow breathing. The study concluded with five additional minutes of regular breathing. NIRS signals were analyzed using a machine learning model to distinguish between normal and simulated pathological breathing. Three features: breathing interval, breathing depth, and O2Hb signal amplitude were extracted from the NIRS data and, when used together, resulted in a weighted average accuracy of 0.87. This study demonstrated that a wearable NIRS sensor can monitor respiratory patterns continuously and non-invasively and we identified three respiratory features that can distinguish between normal and simulated pathological breathing.


Assuntos
COVID-19 , Adulto , COVID-19/diagnóstico , Humanos , Monitorização Fisiológica , Respiração , Espectroscopia de Luz Próxima ao Infravermelho
5.
PLoS One ; 17(5): e0267214, 2022.
Artigo em Inglês | MEDLINE | ID: covidwho-1910592

RESUMO

Since its identification in 2019, Covid-19 has spread to become a global pandemic. Until now, vaccination in its different forms proves to be the most effective measure to control the outbreak and lower the burden of the disease on healthcare systems. This arena has become a prime target to criminal networks that spread counterfeit Covid-19 vaccines across the supply chain mainly for profit. Counterfeit vaccines provide false sense of security to individuals, heightens the risk of exposure and outbreak of the virus, and increase the risk of harm linked to Covid-19 infection. Moreover, the increase in counterfeit vaccines feeds hesitancy towards vaccination and erodes the trust in mass immunisation programmes. It is therefore of paramount importance to work on rapid and reliable methods for vaccine authentication. Subsequently this work utilised a portable and non-destructive near infrared (NIR) spectroscopic method for authentication of Covid-19 vaccines. A total of 405 Covid-19 vaccines samples, alongside their main constituents, were measured as received through glass vials. Spectral quality and bands were inspected by considering the raw spectra of the vaccines. Authentication was explored by applying principal component analysis (PCA) to the multiplicative scatter correction-first derivative spectra. The results showed that NIR spectra of the vaccine featured mainly bands corresponding to the mRNA active ingredient. Fewer bands corresponded to the excipients and protein spectra. The vaccines NIR spectra were strongly absorbing with maximum absorbances up to 2.7 absorbance units and that differentiated them from samples containing normal saline only (constituent reported for counterfeit Covid-19 vaccines). Clustering based on PCA offered optimal authentication of Covid-19 vaccines when applied over the range of 9000-4000 cm-1These findings shed light on the potential of using NIR for analysing Covid-19 vaccines and presents a rapid and effective initial technique for Covid-19 vaccine authentication.


Assuntos
COVID-19 , Vacinas , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Humanos , RNA Mensageiro , Espectroscopia de Luz Próxima ao Infravermelho/métodos
6.
Sensors (Basel) ; 22(12)2022 Jun 10.
Artigo em Inglês | MEDLINE | ID: covidwho-1884320

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic is a worldwide health anxiety. The rapid dispersion of the infection globally results in unparalleled economic, social, and health impacts. The pathogen that causes COVID-19 is known as a severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). A fast and low-cost diagnosis method for COVID-19 disease can play an important role in controlling its proliferation. Near-infrared spectroscopy (NIRS) is a quick, non-destructive, non-invasive, and inexpensive technique for profiling the chemical and physical structures of a wide range of samples. Furthermore, the NIRS has the advantage of incorporating the internet of things (IoT) application for the effective control and treatment of the disease. In recent years, a significant advancement in instrumentation and spectral analysis methods has resulted in a remarkable impact on the NIRS applications, especially in the medical discipline. To date, NIRS has been applied as a technique for detecting various viruses including zika (ZIKV), chikungunya (CHIKV), influenza, hepatitis C, dengue (DENV), and human immunodeficiency (HIV). This review aims to outline some historical and contemporary applications of NIRS in virology and its merit as a novel diagnostic technique for SARS-CoV-2.


Assuntos
COVID-19 , Vírus Chikungunya , Vírus da Dengue , Dengue , Infecção por Zika virus , Zika virus , COVID-19/diagnóstico , Dengue/diagnóstico , Humanos , SARS-CoV-2 , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Infecção por Zika virus/diagnóstico
7.
Sci Rep ; 12(1): 2356, 2022 02 18.
Artigo em Inglês | MEDLINE | ID: covidwho-1706307

RESUMO

Effective testing is essential to control the coronavirus disease 2019 (COVID-19) transmission. Here we report a-proof-of-concept study on hyperspectral image analysis in the visible and near-infrared range for primary screening at the point-of-care of SARS-CoV-2. We apply spectral feature descriptors, partial least square-discriminant analysis, and artificial intelligence to extract information from optical diffuse reflectance measurements from 5 µL fluid samples at pixel, droplet, and patient levels. We discern preparations of engineered lentiviral particles pseudotyped with the spike protein of the SARS-CoV-2 from those with the G protein of the vesicular stomatitis virus in saline solution and artificial saliva. We report a quantitative analysis of 72 samples of nasopharyngeal exudate in a range of SARS-CoV-2 viral loads, and a descriptive study of another 32 fresh human saliva samples. Sensitivity for classification of exudates was 100% with peak specificity of 87.5% for discernment from PCR-negative but symptomatic cases. Proposed technology is reagent-free, fast, and scalable, and could substantially reduce the number of molecular tests currently required for COVID-19 mass screening strategies even in resource-limited settings.


Assuntos
Exsudatos e Transudatos/virologia , Programas de Rastreamento/métodos , SARS-CoV-2/isolamento & purificação , Saliva/virologia , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Testes Imediatos , Estudo de Prova de Conceito
8.
Early Hum Dev ; 166: 105552, 2022 03.
Artigo em Inglês | MEDLINE | ID: covidwho-1683075

RESUMO

BACKGROUND: Partial oxygen saturation (SpO2) increases within minutes during transition from the intrauterine to extrauterine life. This study aims to determine the postnatal course of pulmonary regional oxygen saturation (rSO2) measured by Near-Infrared Spectroscopy (NIRS). METHODS: We conducted an observational study at the delivery room in infants above 35 weeks of gestation who did not need resuscitation and did not develop respiratory distress. Preductal pulse oximetry (Covidien NellcorTM) and right pulmonary apex oxygen saturation (raSO2) and basal oxygen saturation (rbSO2) (Covidien INVOSTM) were measured, starting from the postnatal third minute of life, until the 15th minute. The correlations between SpO2 and pulmonary rSO2 were analyzed. RESULTS: Of the 110 infants included in the study, 87 were term and 23 were late preterms. The gestational age and birth weight were 38.5 ± 1.36 weeks and 3285 ± 508 g, respectively. Median (5th-95th percentile) raSO2 and rbSO2 were 79% (58-95%) and 78% (46-95%) at the third minute, respectively. The rSO2 values measured from both sides increased and reached a steady-state around postnatal 9 min, similar to SpO2 values. The pulmonary NIRS values were significantly higher for babies born by C-Section compared to babies born by vaginal delivery (p < 0.05). CONCLUSION: We found that rSO2 measurements increased within minutes in the postnatal period in late preterm and term babies without respiratory distress and reached a plateau at the postnatal 9th minute. The normal values obtained from this preliminary study may be used to predict the prognosis of cases with respiratory distress.


Assuntos
Saturação de Oxigênio , Oxigênio , Feminino , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Oximetria/métodos , Gravidez , Espectroscopia de Luz Próxima ao Infravermelho
9.
Biol Res ; 54(1): 39, 2021 Dec 14.
Artigo em Inglês | MEDLINE | ID: covidwho-1577124

RESUMO

BACKGROUND: The aim of the study was to investigate the effect of mild cerebral hypoxia on haemoglobin oxygenation (HbO2), cerebrospinal fluid dynamics and cardiovascular physiology. To achieve this goal, four signals were recorded simultaneously: blood pressure, heart rate / electrocardiogram, HbO2 from right hemisphere and changes of subarachnoid space (SAS) width from left hemisphere. Signals were registered from 30 healthy, young participants (2 females and 28 males, body mass index = 24.5 ± 2.3 kg/m2, age 30.8 ± 13.4 years). RESULTS: We analysed the recorded signals using wavelet transform and phase coherence. We demonstrated for the first time that in healthy subjects exposed to mild poikilokapnic hypoxia there were increases in very low frequency HbO2 oscillations (< 0.052 Hz) in prefrontal cortex. Additionally, SAS fluctuation diminished in the whole frequency range which could be explained by brain oedema. CONCLUSIONS: Consequently the study provides insight into mechanisms governing brain response to a mild hypoxic challenge. Our study supports the notion that HbO2 and SAS width monitoring might be beneficial for patients with acute lung disease.


Assuntos
Circulação Cerebrovascular , Pneumopatias , Adolescente , Adulto , Feminino , Hemoglobinas , Humanos , Hipóxia , Masculino , Córtex Pré-Frontal , Espectroscopia de Luz Próxima ao Infravermelho , Adulto Jovem
10.
Toxicol Appl Pharmacol ; 434: 115796, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: covidwho-1510333

RESUMO

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has required the urgent development of new therapies, among which passive immunotherapy is contemplated. CoviFab (INM005) is a RBD-specific F(ab')2 fragment derived from equine polyclonal antibodies. We investigate their preclinical security and biodistribution by in vivo and ex vivo NIR imaging after intravenous administration of a dose of 4 mg/kg at time 0 and 48 h. Images were taken at 1, 12, 24, 36, 48, 49, 60, 72, 84, 96, 108, 120, 132 and 144 h after the first intravenous injection. At 96 and 144 h, mice were sacrificed for haematology, serum chemistry, clinical pathology, histopathology and ex vivo imaging. The biodistribution profile was similar in all organs studied, with the highest fluorescence at 1 h after each injection, gradually decreasing after that each one and until the end of the study (144 h). The toxicology study revealed no significant changes in the haematology and serum chemistry parameters. Further, there were no changes in the gross and histological examination of organs. Nonclinical data of the current study confirm that CoviFab is safe, without observable adverse effects in mice. Furthermore, we confirm that bioimaging studies are a useful approach in preclinical trials to determine biodistribution.


Assuntos
Anticorpos Antivirais/metabolismo , Tratamento Farmacológico da COVID-19 , Receptores Imunológicos/metabolismo , Proteínas Recombinantes/metabolismo , SARS-CoV-2/metabolismo , Administração Intravenosa , Animais , Anticorpos Antivirais/administração & dosagem , Anticorpos Antivirais/efeitos adversos , COVID-19/metabolismo , COVID-19/prevenção & controle , Células HEK293 , Cavalos , Humanos , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Transgênicos , Receptores Imunológicos/administração & dosagem , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/efeitos adversos , SARS-CoV-2/efeitos dos fármacos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Distribuição Tecidual/efeitos dos fármacos , Distribuição Tecidual/fisiologia
11.
Sensors (Basel) ; 21(21)2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: covidwho-1512555

RESUMO

Despite the wide range of clinical and research applications, the reliability of the absolute oxygenation measurements of continuous wave near-infrared spectroscopy sensors is often questioned, partially due to issues of standardization. In this study, we have compared the performances of 13 units of a continuous wave near-infrared spectroscopy device (PortaMon, Artinis Medical Systems, NL) to test their suitability for being used in the HEMOCOVID-19 clinical trial in 10 medical centers around the world. Detailed phantom and in vivo tests were employed to measure the precision and reproducibility of measurements of local blood oxygen saturation and total hemoglobin concentration under different conditions: for different devices used, different operators, for probe repositioning over the same location, and over time (hours/days/months). We have detected systematic differences between devices when measuring phantoms (inter-device variability, <4%), which were larger than the intra-device variability (<1%). This intrinsic variability is in addition to the variability during in vivo measurements on the forearm muscle resulting from errors in probe positioning and intrinsic physiological noise (<9%), which was also larger than the inter-device differences (<3%) during the same test. Lastly, we have tested the reproducibility of the protocol of the HEMOCOVID-19 clinical trial; that is, forearm muscle oxygenation monitoring during vascular occlusion tests over days. Overall, our conclusion is that these devices can be used in multi-center trials but care must be taken to characterize, follow-up, and statistically account for inter-device variability.


Assuntos
Oximetria , Espectroscopia de Luz Próxima ao Infravermelho , Oxigênio , Consumo de Oxigênio , Reprodutibilidade dos Testes
12.
Proc Natl Acad Sci U S A ; 118(41)2021 10 12.
Artigo em Inglês | MEDLINE | ID: covidwho-1486398

RESUMO

The COVID-19 pandemic led to widespread mandates requiring the wearing of face masks, which led to debates on their benefits and possible adverse effects. To that end, the physiological effects at the systemic and at the brain level are of interest. We have investigated the effect of commonly available face masks (FFP2 and surgical) on cerebral hemodynamics and oxygenation, particularly microvascular cerebral blood flow (CBF) and blood/tissue oxygen saturation (StO2), measured by transcranial hybrid near-infrared spectroscopies and on systemic physiology in 13 healthy adults (ages: 23 to 33 y). The results indicate small but significant changes in cerebral hemodynamics while wearing a mask. However, these changes are comparable to those of daily life activities. This platform and the protocol provides the basis for large or targeted studies of the effects of mask wearing in different populations and while performing critical tasks.


Assuntos
Encéfalo/fisiologia , Máscaras , Atividades Cotidianas , Adulto , Encéfalo/irrigação sanguínea , Encéfalo/metabolismo , COVID-19/prevenção & controle , Feminino , Voluntários Saudáveis , Hemodinâmica , Humanos , Masculino , Microcirculação , Monitorização Fisiológica , Oxigênio/metabolismo , SARS-CoV-2 , Espectroscopia de Luz Próxima ao Infravermelho , Adulto Jovem
13.
J Am Chem Soc ; 143(45): 18827-18831, 2021 11 17.
Artigo em Inglês | MEDLINE | ID: covidwho-1483090

RESUMO

Despite the importance of rapid and accurate detection of SARS-CoV-2 in controlling the COVID-19 pandemic, current diagnostic methods are static and unable to distinguish between viable/nonviable virus or directly reflect viral replication activity. Real-time imaging of protease activity specific to SARS-CoV-2 can overcome these issues but remains lacking. Herein, we report a near-infrared fluorescence (NIRF) activatable molecular probe (SARS-CyCD) for detection of SARS-CoV-2 protease in living mice. The probe comprises a hemicyanine fluorophore caged with a protease peptide substrate and a cyclodextrin unit, which function as an NIRF signaling moiety and a renal-clearable enabler, respectively. The peptide substrate of SARS-CyCD can be specifically cleaved by SARS-CoV-2 main protease (Mpro), resulting in NIRF signal activation and liberation of the renal-clearable fluorescent fragment (CyCD). Such a design not only allows sensitive detection of Mpro in the lungs of living mice after intratracheal administration but also permits optical urinalysis of SARS-CoV-2 infection. Thus, this study presents an in vivo sensor that holds potential in preclinical high-throughput drug screening and clinical diagnostics for respiratory viral infections.


Assuntos
COVID-19/diagnóstico , Rim/metabolismo , Sondas Moleculares/metabolismo , Imagem Óptica/métodos , Animais , COVID-19/virologia , Corantes Fluorescentes/análise , Corantes Fluorescentes/metabolismo , Humanos , Pulmão/metabolismo , Camundongos , Sondas Moleculares/análise , SARS-CoV-2/enzimologia , SARS-CoV-2/isolamento & purificação , Espectroscopia de Luz Próxima ao Infravermelho , Urinálise , Proteínas da Matriz Viral/metabolismo
15.
Sci Rep ; 11(1): 16201, 2021 08 10.
Artigo em Inglês | MEDLINE | ID: covidwho-1351977

RESUMO

Optical spectroscopic techniques have been commonly used to detect the presence of biofilm-forming pathogens (bacteria and fungi) in the agro-food industry. Recently, near-infrared (NIR) spectroscopy revealed that it is also possible to detect the presence of viruses in animal and vegetal tissues. Here we report a platform based on visible and NIR (VNIR) hyperspectral imaging for non-contact, reagent free detection and quantification of laboratory-engineered viral particles in fluid samples (liquid droplets and dry residue) using both partial least square-discriminant analysis and artificial feed-forward neural networks. The detection was successfully achieved in preparations of phosphate buffered solution and artificial saliva, with an equivalent pixel volume of 4 nL and lowest concentration of 800 TU·[Formula: see text]L-1. This method constitutes an innovative approach that could be potentially used at point of care for rapid mass screening of viral infectious diseases and monitoring of the SARS-CoV-2 pandemic.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Infecções por Lentivirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Células HEK293 , Humanos , Processamento de Imagem Assistida por Computador/normas , Lentivirus/isolamento & purificação , Lentivirus/patogenicidade , Infecções por Lentivirus/virologia , Técnicas de Diagnóstico Molecular/normas , Sistemas Automatizados de Assistência Junto ao Leito , Saliva/virologia , Sensibilidade e Especificidade , Espectroscopia de Luz Próxima ao Infravermelho/normas
16.
Chem Commun (Camb) ; 57(51): 6229-6232, 2021 Jun 24.
Artigo em Inglês | MEDLINE | ID: covidwho-1246405

RESUMO

Tracking the viral progression of SARS-CoV-2 in COVID-19 infected body tissues is an emerging need of the current pandemic. Imaging at near infrared second biological window (NIR-II) offers striking benefits over the other technologies to explore deep-tissue information. Here we design, synthesise and characterise a molecular probe that selectively targets the N-gene of SARS-CoV-2. Highly specific antisense oligonucleotides (ASOs) were conjugated to lead sulfide quantum dots using a UV-triggered thiol-ene click chemistry for the recognition of viral RNA. Our ex vivo imaging studies demonstrated that the probe exhibits aggregation induced NIR-II emission only in presence of SARS-CoV-2 RNA which can be attributed to the efficient hybridisation of the ASOs with their target RNA strands.


Assuntos
COVID-19/diagnóstico , COVID-19/virologia , Corantes Fluorescentes/química , Oligonucleotídeos Antissenso/química , Pontos Quânticos/química , SARS-CoV-2/isolamento & purificação , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Animais , COVID-19/diagnóstico por imagem , COVID-19/metabolismo , Química Click/métodos , Corantes Fluorescentes/síntese química , Humanos , Pulmão/diagnóstico por imagem , Pulmão/metabolismo , Pulmão/virologia , Nanopartículas Metálicas/química , Camundongos , Camundongos Endogâmicos BALB C , Modelos Animais , SARS-CoV-2/genética , SARS-CoV-2/metabolismo
17.
Sensors (Basel) ; 21(9)2021 May 09.
Artigo em Inglês | MEDLINE | ID: covidwho-1238950

RESUMO

This study innovatively proposes a feature fusion technique to determine fatty acid content during rice storage. Firstly, a self-developed olfactory visualization sensor was used to capture the odor information of rice samples at different storage periods and a portable spectroscopy system was employed to collect the near-infrared (NIR) spectra during rice storage. Then, principal component analysis (PCA) was performed on the pre-processed olfactory visualization sensor data and the NIR spectra, and the number of the best principal components (PCs) based on the single technique model was optimized during the backpropagation neural network (BPNN) modeling. Finally, the optimal PCs were fused at the feature level, and a BPNN detection model based on the fusion feature was established to achieve rapid measurement of fatty acid content during rice storage. The experimental results showed that the best BPNN model based on the fusion feature had a good predictive performance where the correlation coefficient (RP) was 0.9265, and the root mean square error (RMSEP) was 1.1005 mg/100 g. The overall results demonstrate that the detection accuracy and generalization performance of the feature fusion model are an improvement on the single-technique data model; and the results of this study can provide a new technical method for high-precision monitoring of grain storage quality.


Assuntos
Oryza , Algoritmos , Ácidos Graxos , Análise dos Mínimos Quadrados , Redes Neurais de Computação , Espectroscopia de Luz Próxima ao Infravermelho
18.
ACS Appl Mater Interfaces ; 13(8): 10321-10327, 2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: covidwho-1087402

RESUMO

Early diagnosis of SARS-CoV-2 infection is critical for facilitating proper containment procedures, and a rapid, sensitive antigen assay is a critical step in curbing the pandemic. In this work, we report the use of a high-purity semiconducting (sc) single-walled carbon nanotube (SWCNT)-based field-effect transistor (FET) decorated with specific binding chemistry to assess the presence of SARS-CoV-2 antigens in clinical nasopharyngeal samples. Our SWCNT FET sensors, with functionalization of the anti-SARS-CoV-2 spike protein antibody (SAb) and anti-nucleocapsid protein antibody, detected the S antigen (SAg) and N antigen (NAg), reaching a limit of detection of 0.55 fg/mL for SAg and 0.016 fg/mL for NAg in calibration samples. SAb-functionalized FET sensors also exhibited good sensing performance in discriminating positive and negative clinical samples, indicating a proof of principle for use as a rapid COVID-19 antigen diagnostic tool with high analytical sensitivity and specificity at low cost.


Assuntos
Antígenos Virais/análise , Técnicas Biossensoriais , Teste para COVID-19/instrumentação , Nanotubos de Carbono/química , Semicondutores , Transistores Eletrônicos , Teste para COVID-19/métodos , Calibragem , Eletrodos , Ouro , Humanos , Limite de Detecção , Teste de Materiais , Microscopia de Força Atômica , Microscopia de Fluorescência , Nanotecnologia , SARS-CoV-2 , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta , Espectroscopia de Luz Próxima ao Infravermelho , Análise Espectral Raman , Glicoproteína da Espícula de Coronavírus/análise
19.
Food Chem ; 353: 128718, 2021 Aug 15.
Artigo em Inglês | MEDLINE | ID: covidwho-947222

RESUMO

Fraud in the food supply system will be exacerbated by shortages caused by climate change and COVID-19's impact. The dried herbs market exemplifies complex supply chains attractive to criminals seeking financial gain. Real-time remote testing is achievable through development of globally accessible chemometric models for portable near infrared devices, deployed throughout supply chains. This study describes building of models for detection of oregano adulteration, on portable near infrared devices, and comparison to a laboratory-based Fourier-Transform Infrared spectroscopy method. 33/34 portable devices were able to correctly classify 5 out of 6 samples successfully with all adulterated samples being correctly classified following the use of appropriate transferability pre-processing routines. The devices native setup shows limited ability to perform a true screening of oregano using the setup offered. However modifications to the setup could in the future offer a solution that facilitates fit-for-purpose real time detection of adulterated samples within the supply chain.


Assuntos
Contaminação de Alimentos/análise , Origanum/química , Laboratórios , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Espectroscopia de Luz Próxima ao Infravermelho
20.
Anal Chem ; 92(19): 13396-13404, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: covidwho-933642

RESUMO

Rapid, accurate, reliable, and risk-free tracking of pathogenic microorganisms at the single-cell level is critical to achieve efficient source control and prevent outbreaks of microbial infectious diseases. For the first time, we report a promising approach for integrating the concepts of a remarkably large Stokes shift and dual-recognition into a single matrix to develop a pathogenic microorganism stimuli-responsive ratiometric fluorescent nanoprobe with speed, cost efficiency, stability, ultrahigh specificity, and sensitivity. As a proof-of-concept, we selected the Gram-positive bacterium Staphylococcus aureus (S. aureus) as the target analyte model, which easily bound to its recognition aptamer and the broad-spectrum glycopeptide antibiotic vancomycin (Van). To improve the specificity and short sample-to-answer time, we employed classic noncovalent π-π stacking interactions as a driving force to trigger the binding of Van and aptamer dual-functionalized near-infrared (NIR) fluorescent Apt-Van-QDs to the surface of an unreported blue fluorescent π-rich electronic carbon nanoparticles (CNPs), achieving S. aureus stimuli-responsive ratiometric nanoprobe Apt-Van-QDs@CNPs. In the assembly of Apt-Van-QDs@CNPs, the blue CNPs (energy donor) and NIR Apt-Van-QDs (energy acceptor) became close to allow the fluorescence resonance energy transfer (FRET) process, leading to a remarkable blue fluorescence quenching for the CNPs at ∼465 nm and a clear NIR fluorescence enhancement for Apt-Van-QDs at ∼725 nm. In the presence of S. aureus, the FRET process from CNPs to Apt-Van-QDs was disrupted, causing the nanoprobe Apt-Van-QDs@CNPs to display a ratiometric fluorescent response to S. aureus, which exhibited a large Stokes shift of ∼260 nm and rapid sample-to-answer detection time (∼30.0 min). As expected, the nanoprobe Apt-Van-QDs@CNPs showed an ultrahigh specificity for ratiometric fluorescence detection of S. aureus with a good detection limit of 1.0 CFU/mL, allowing the assay at single-cell level. Moreover, we also carried out the precise analysis of S. aureus in actual samples with acceptable results. We believe that this work offers new insight into the rational design of efficient ratiometric nanoprobes for rapid on-site accurate screening of pathogenic microorganisms at the single-cell level in the early stages, especially during the worldwide spread of COVID-19 today.


Assuntos
Bactérias/química , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/microbiologia , Técnicas Biossensoriais/métodos , Corantes Fluorescentes/síntese química , Nanotecnologia/métodos , Antibacterianos/farmacologia , Aptâmeros de Nucleotídeos , COVID-19 , Infecções por Coronavirus/complicações , Infecções por Coronavirus/microbiologia , Fluorescência , Transferência Ressonante de Energia de Fluorescência , Microbiologia de Alimentos/métodos , Humanos , Nanopartículas , Pandemias , Pneumonia Viral/complicações , Pneumonia Viral/microbiologia , Sensibilidade e Especificidade , Espectroscopia de Luz Próxima ao Infravermelho , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/química , Vancomicina/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA